2023-05-12 23:55:26 +02:00
{
"id" : "CVE-2023-25005" ,
"sourceIdentifier" : "psirt@autodesk.com" ,
"published" : "2023-05-12T21:15:09.220" ,
2023-05-26 20:00:33 +00:00
"lastModified" : "2023-05-26T18:17:22.953" ,
"vulnStatus" : "Analyzed" ,
2023-05-12 23:55:26 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A maliciously crafted DLL file can be forced to read beyond allocated boundaries in Autodesk InfraWorks 2023, and 2021 when parsing the DLL files could lead to a resource injection vulnerability."
}
] ,
2023-05-26 20:00:33 +00:00
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-427"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "2021.0" ,
"versionEndExcluding" : "2021.2" ,
"matchCriteriaId" : "2ED3976D-7AEB-4682-A992-39E3FFF21613"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "2023.0" ,
"versionEndExcluding" : "2023.1" ,
"matchCriteriaId" : "9B5ED076-764C-400E-8DAD-7F9E0793FD7F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "E8799159-8E69-4463-96D9-920E64A675B4"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_1:*:*:*:*:*:*" ,
"matchCriteriaId" : "DDAE8B1C-5799-4FCB-AA1F-E01C72C545B1"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_2:*:*:*:*:*:*" ,
"matchCriteriaId" : "BAB28476-5965-441D-AAEF-F76F7C599F3F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_3:*:*:*:*:*:*" ,
"matchCriteriaId" : "67C2219C-5B50-4E46-B1F0-68218F1E5AF5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_4:*:*:*:*:*:*" ,
"matchCriteriaId" : "E5684221-8B7C-4ADA-A1A8-727E7F0F67BD"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_5:*:*:*:*:*:*" ,
"matchCriteriaId" : "EB247C2B-8221-457A-99F9-39D75D4DB8E4"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_6:*:*:*:*:*:*" ,
"matchCriteriaId" : "E3E63C7B-C4A5-4722-88A5-6801AA086915"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_7:*:*:*:*:*:*" ,
"matchCriteriaId" : "8CBCFD6F-2195-48AA-B6A9-8EBB7BF1F047"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_8:*:*:*:*:*:*" ,
"matchCriteriaId" : "280DEA0C-EF21-4C54-8C9D-FC83152F2C86"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2021.2:hotfix_9:*:*:*:*:*:*" ,
"matchCriteriaId" : "533A6090-B202-49D4-B0C7-7C189EB282AA"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:autodesk:infraworks:2023.1:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "71061947-E7CE-44C8-8DAE-779AEDBEC170"
}
]
}
]
}
] ,
2023-05-12 23:55:26 +02:00
"references" : [
{
"url" : "https://www.autodesk.com/trust/security-advisories/adsk-sa-2023-0006" ,
2023-05-26 20:00:33 +00:00
"source" : "psirt@autodesk.com" ,
"tags" : [
"Vendor Advisory"
]
2023-05-12 23:55:26 +02:00
}
]
}