"id" : "CVE-2024-37368" ,
"sourceIdentifier" : "PSIRT@rockwellautomation.com" ,
"published" : "2024-06-14T15:15:52.100" ,
2024-06-17 14:03:54 +00:00
"lastModified" : "2024-06-17T12:42:04.623" ,
"vulnStatus" : "Awaiting Analysis" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2024-06-14 16:03:12 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A user authentication vulnerability exists in the Rockwell Automation\u00a0FactoryTalk\u00ae View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification."
2024-06-17 14:03:54 +00:00
} ,
{
"lang" : "es" ,
"value" : "Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Debido a la falta de autenticaci\u00f3n adecuada, esta acci\u00f3n se permite sin una verificaci\u00f3n de autenticaci\u00f3n adecuada."
2024-06-14 16:03:12 +00:00
}
] ,
2024-07-14 02:06:08 +00:00
"metrics" : {
"cvssMetricV40" : [
{
"source" : "PSIRT@rockwellautomation.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "4.0" ,
"vectorString" : "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"attackRequirements" : "PRESENT" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"vulnerableSystemConfidentiality" : "HIGH" ,
"vulnerableSystemIntegrity" : "NONE" ,
"vulnerableSystemAvailability" : "NONE" ,
"subsequentSystemConfidentiality" : "NONE" ,
"subsequentSystemIntegrity" : "NONE" ,
"subsequentSystemAvailability" : "NONE" ,
"exploitMaturity" : "NOT_DEFINED" ,
"confidentialityRequirements" : "NOT_DEFINED" ,
"integrityRequirements" : "NOT_DEFINED" ,
"availabilityRequirements" : "NOT_DEFINED" ,
"modifiedAttackVector" : "NOT_DEFINED" ,
"modifiedAttackComplexity" : "NOT_DEFINED" ,
"modifiedAttackRequirements" : "NOT_DEFINED" ,
"modifiedPrivilegesRequired" : "NOT_DEFINED" ,
"modifiedUserInteraction" : "NOT_DEFINED" ,
"modifiedVulnerableSystemConfidentiality" : "NOT_DEFINED" ,
"modifiedVulnerableSystemIntegrity" : "NOT_DEFINED" ,
"modifiedVulnerableSystemAvailability" : "NOT_DEFINED" ,
"modifiedSubsequentSystemConfidentiality" : "NOT_DEFINED" ,
"modifiedSubsequentSystemIntegrity" : "NOT_DEFINED" ,
"modifiedSubsequentSystemAvailability" : "NOT_DEFINED" ,
"safety" : "NOT_DEFINED" ,
"automatable" : "NOT_DEFINED" ,
"recovery" : "NOT_DEFINED" ,
"valueDensity" : "NOT_DEFINED" ,
"vulnerabilityResponseEffort" : "NOT_DEFINED" ,
"providerUrgency" : "NOT_DEFINED" ,
"baseScore" : 8.2 ,
"baseSeverity" : "HIGH"
}
}
]
} ,
2024-06-14 16:03:12 +00:00
"weaknesses" : [
{
"source" : "PSIRT@rockwellautomation.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-287"
}
]
}
] ,
"references" : [
{
"url" : "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1676.html" ,
"source" : "PSIRT@rockwellautomation.com"
}
]
}