123 lines
3.4 KiB
JSON
Raw Normal View History

{
"id": "CVE-2023-29115",
"sourceIdentifier": "cve@asrg.io",
"published": "2024-11-05T15:15:21.667",
"lastModified": "2024-11-08T16:08:01.997",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In certain conditions a request directed to the Waybox Enel X Web management application could cause a denial-of-service (e.g. reboot)."
},
{
"lang": "es",
"value": " En determinadas condiciones, una solicitud dirigida a la aplicaci\u00f3n de gesti\u00f3n web Waybox Enel X podr\u00eda provocar una denegaci\u00f3n de servicio (por ejemplo, reinicio)."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cve@asrg.io",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "cve@asrg.io",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:enelx:waybox_pro_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.1.1.0_jb3vu096a",
"matchCriteriaId": "B7B70D3C-2FBD-4BEA-8ADB-0712CBC60CDE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:enelx:waybox_pro:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "B4793B11-455A-4C29-A1EC-22CE8DDFEDCF"
}
]
}
]
}
],
"references": [
{
"url": "https://support-emobility.enelx.com/content/dam/enelxmobility/italia/documenti/manuali-schede-tecniche/Waybox-3-Security-Bulletin-06-2024-V1.pdf",
"source": "cve@asrg.io",
"tags": [
"Vendor Advisory"
]
}
]
}