208 lines
7.8 KiB
JSON
Raw Normal View History

{
"id": "CVE-2023-38524",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-08-08T10:15:15.627",
"lastModified": "2024-11-21T08:13:45.503",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Parasolid V35.1 (Todas las versiones inferiores a V35.1. 171), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). Las aplicaciones afectadas contienen desviaci\u00f3n de puntero nulo al analizar archivos X_T especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 2.0,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "PASSIVE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"baseScore": 3.3,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "LOW"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "34.1",
"versionEndExcluding": "34.1.258",
"matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.0",
"versionEndExcluding": "35.0.254",
"matchCriteriaId": "0B5F1A02-44EB-45AA-B071-764B64473313"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.1",
"versionEndExcluding": "35.1.171",
"matchCriteriaId": "EA7FF725-2396-492A-8B97-CA77B4EFCC48"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.1",
"versionEndExcluding": "14.1.0.11",
"matchCriteriaId": "9EF3388B-D057-4DB9-96AE-B6F4678FE5B8"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.2",
"versionEndExcluding": "14.2.0.6",
"matchCriteriaId": "7E1EFF45-5311-4E89-B736-271EF3C0C232"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.3",
"versionEndExcluding": "14.3.0.3",
"matchCriteriaId": "99F0D457-7D65-40DC-BCFA-339FA5648709"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-407785.html",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}