2023-09-13 14:00:30 +00:00
{
"id" : "CVE-2023-29183" ,
"sourceIdentifier" : "psirt@fortinet.com" ,
"published" : "2023-09-13T13:15:08.367" ,
2023-09-15 14:00:30 +00:00
"lastModified" : "2023-09-15T13:23:51.840" ,
"vulnStatus" : "Analyzed" ,
2023-09-13 14:00:30 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "An improper neutralization of input during web page generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting."
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-09-15 14:00:30 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "REQUIRED" ,
"scope" : "CHANGED" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "LOW" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 5.4 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.3 ,
"impactScore" : 2.7
} ,
2023-09-13 14:00:30 +00:00
{
"source" : "psirt@fortinet.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 8.0 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 2.1 ,
"impactScore" : 5.9
}
]
} ,
2023-09-15 14:00:30 +00:00
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-79"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.0.0" ,
"versionEndExcluding" : "7.0.11" ,
"matchCriteriaId" : "A5D70694-BB02-43E2-8F74-D50D9D4C5E3C"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.2.0" ,
"versionEndExcluding" : "7.2.5" ,
"matchCriteriaId" : "122518E7-EA43-4240-AAFB-61AD2AA28A2B"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "6.2.0" ,
"versionEndExcluding" : "6.2.15" ,
"matchCriteriaId" : "05454D49-17D8-4A7D-92C8-B33B006A35DA"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "6.4.0" ,
"versionEndExcluding" : "6.4.13" ,
"matchCriteriaId" : "B153B056-24AE-41C4-B644-65E080C18360"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.0.0" ,
"versionEndExcluding" : "7.0.12" ,
"matchCriteriaId" : "39A6C2A7-21A4-4BB5-A3B6-9466E5CEA296"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "7.2.0" ,
"versionEndExcluding" : "7.2.5" ,
"matchCriteriaId" : "4562BDF7-D894-4CD8-95AC-9409FDEBE73F"
}
]
}
]
}
] ,
2023-09-13 14:00:30 +00:00
"references" : [
{
"url" : "https://fortiguard.com/psirt/FG-IR-23-106" ,
2023-09-15 14:00:30 +00:00
"source" : "psirt@fortinet.com" ,
"tags" : [
"Vendor Advisory"
]
2023-09-13 14:00:30 +00:00
}
]
}