2023-08-18 12:00:33 +00:00
{
"id" : "CVE-2023-39454" ,
"sourceIdentifier" : "vultures@jpcert.or.jp" ,
"published" : "2023-08-18T10:15:12.280" ,
2023-08-23 18:00:37 +00:00
"lastModified" : "2023-08-23T16:48:10.200" ,
"vulnStatus" : "Analyzed" ,
2023-08-18 12:00:33 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "Buffer overflow vulnerability in WRC-X1800GS-B v1.13 and earlier, WRC-X1800GSA-B v1.13 and earlier, and WRC-X1800GSH-B v1.13 and earlier allows an unauthenticated attacker to execute arbitrary code."
}
] ,
2023-08-23 18:00:37 +00:00
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-120"
}
]
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:elecom:wrc-x1800gs-b_firmware:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "1.13" ,
"matchCriteriaId" : "180230C8-AC98-43BA-8FB9-D32D75B5D004"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:elecom:wrc-x1800gs-b:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "95667B22-5F8C-4774-9E69-2F4B9AF595AC"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:elecom:wrc-x1800gsa-b_firmware:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "1.13" ,
"matchCriteriaId" : "09B2B059-11E9-4D03-A162-B06E56649167"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:elecom:wrc-x1800gsa-b:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "3842FA46-4CA2-4ECE-8632-2C74E8D97CDB"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:elecom:wrc-x1800gsh-b_firmware:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "1.13" ,
"matchCriteriaId" : "5DD8EAED-69F6-47ED-B521-E675AD501B38"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:elecom:wrc-x1800gsh-b:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "20EA8B33-784F-44E8-B215-DC2554709100"
}
]
}
]
}
] ,
2023-08-18 12:00:33 +00:00
"references" : [
{
"url" : "https://jvn.jp/en/vu/JVNVU91630351/" ,
2023-08-23 18:00:37 +00:00
"source" : "vultures@jpcert.or.jp" ,
"tags" : [
"Third Party Advisory"
]
2023-08-18 12:00:33 +00:00
} ,
{
"url" : "https://www.elecom.co.jp/news/security/20230711-01/" ,
2023-08-23 18:00:37 +00:00
"source" : "vultures@jpcert.or.jp" ,
"tags" : [
"Vendor Advisory"
]
2023-08-18 12:00:33 +00:00
}
]
}