2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2019-16899" ,
"sourceIdentifier" : "cve@mitre.org" ,
"published" : "2019-09-26T01:15:11.230" ,
2024-11-23 11:10:51 +00:00
"lastModified" : "2024-11-21T04:31:18.047" ,
"vulnStatus" : "Modified" ,
2024-12-08 03:06:42 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "In Advantech WebAccess/HMI Designer 2.1.9.31, Data from a Faulting Address controls Code Flow starting at PM_V3!CTagInfoThreadBase::GetNICInfo+0x0000000000512918."
} ,
{
"lang" : "es" ,
"value" : "En Advantech WebAccess/HMI Designer versi\u00f3n 2.1.9.31, los Datos desde una Direcci\u00f3n en Fallo controlan el Flujo de C\u00f3digo que inicia en PM_V3!CTagInfoThreadBase::GetNICInfo+0x0000000000512918."
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" ,
2024-11-23 11:10:51 +00:00
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
2024-11-23 11:10:51 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:L/Au:N/C:N/I:N/A:P" ,
2024-11-23 11:10:51 +00:00
"baseScore" : 5.0 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "LOW" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
2024-11-23 11:10:51 +00:00
"availabilityImpact" : "PARTIAL"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "MEDIUM" ,
"exploitabilityScore" : 10.0 ,
"impactScore" : 2.9 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : false
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-noinfo"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:advantech:webaccess\\/hmi_designer:2.1.9.31:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "528741A9-29CD-4AD6-8CFD-A50AE7949C6C"
}
]
}
]
}
] ,
"references" : [
{
"url" : "http://code610.blogspot.com/2019/09/crashing-webaccesshmi-designer-21931.html" ,
"source" : "cve@mitre.org" ,
"tags" : [
"Third Party Advisory"
]
2024-11-23 11:10:51 +00:00
} ,
{
"url" : "http://code610.blogspot.com/2019/09/crashing-webaccesshmi-designer-21931.html" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Third Party Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}