2024-12-11 19:04:27 +00:00
{
"id" : "CVE-2024-8496" ,
"sourceIdentifier" : "3c1d8aa1-5a33-4ea4-8992-aadd6440af75" ,
"published" : "2024-12-11T17:15:21.390" ,
2024-12-13 21:03:43 +00:00
"lastModified" : "2024-12-13T19:42:40.417" ,
"vulnStatus" : "Analyzed" ,
2024-12-11 19:04:27 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "Under specific circumstances, insecure permissions in Ivanti Workspace Control before version 10.18.40.0 allows a local authenticated attacker to achieve local privilege escalation."
2024-12-13 21:03:43 +00:00
} ,
{
"lang" : "es" ,
"value" : "En circunstancias espec\u00edficas, los permisos inseguros en Ivanti Workspace Control anterior a la versi\u00f3n 10.18.40.0 permiten que un atacante autenticado local logre una escalada de privilegios locales."
2024-12-11 19:04:27 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "3c1d8aa1-5a33-4ea4-8992-aadd6440af75" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
2024-12-13 21:03:43 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
2024-12-11 19:04:27 +00:00
}
]
} ,
"weaknesses" : [
{
"source" : "3c1d8aa1-5a33-4ea4-8992-aadd6440af75" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-276"
}
]
2024-12-13 21:03:43 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-276"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:ivanti:workspace_control:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "10.18.30.0" ,
"versionEndExcluding" : "10.18.40.0" ,
"matchCriteriaId" : "E1DDE59E-0BF6-4787-BCC9-F7195056FD20"
}
]
}
]
2024-12-11 19:04:27 +00:00
}
] ,
"references" : [
{
"url" : "https://forums.ivanti.com/s/article/December-2024-Security-Advisory-Ivanti-Workspace-Control-IWC-CVE-2024-8496" ,
2024-12-13 21:03:43 +00:00
"source" : "3c1d8aa1-5a33-4ea4-8992-aadd6440af75" ,
"tags" : [
"Vendor Advisory"
]
2024-12-11 19:04:27 +00:00
}
]
}