2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2021-37190" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2021-09-14T11:15:25.940" ,
"lastModified" : "2021-09-23T19:18:22.230" ,
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user."
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). El software afectado presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n que podr\u00eda permitir a un atacante recuperar la conexi\u00f3n VPN de un usuario conocido"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.3 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 1.4
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:A/AC:L/Au:N/C:P/I:N/A:N" ,
"accessVector" : "ADJACENT_NETWORK" ,
"accessComplexity" : "LOW" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "PARTIAL" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 3.3
} ,
"baseSeverity" : "LOW" ,
"exploitabilityScore" : 6.5 ,
"impactScore" : 2.9 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : false
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-200"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "3.0" ,
"matchCriteriaId" : "F65F9901-F4BD-4484-9749-D5022245D686"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "4F03BAD5-7B90-4212-ACBC-3C878C02CDAA"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*" ,
"matchCriteriaId" : "E5BACE03-50A7-4279-8CA5-2BB95224D485"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
}
]
}