2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-27639" ,
"sourceIdentifier" : "secure@intel.com" ,
"published" : "2022-11-11T16:15:13.700" ,
2024-04-04 08:46:00 +00:00
"lastModified" : "2023-08-08T14:21:49.707" ,
2023-04-24 12:24:31 +02:00
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "Incomplete cleanup in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via adjacent access."
2024-04-04 08:46:00 +00:00
} ,
{
"lang" : "es" ,
"value" : "La limpieza incompleta en alg\u00fan software del m\u00f3dem Intel(R) XMM(TM) 7560 anterior a la versi\u00f3n M2_7560_R_01.2146.00 puede permitir que un usuario privilegiado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso adyacente."
2023-04-24 12:24:31 +02:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "NONE" ,
"scope" : "CHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 8.4 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.7 ,
"impactScore" : 6.0
} ,
{
"source" : "secure@intel.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "HIGH" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "NONE" ,
"scope" : "CHANGED" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 5.4 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 1.0 ,
"impactScore" : 4.0
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
2024-04-04 08:46:00 +00:00
"value" : "CWE-459"
2023-04-24 12:24:31 +02:00
}
]
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:intel:xmm_7560_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "m2_7560_r_01.2146.00" ,
"matchCriteriaId" : "6A636ED6-D919-498E-B1BC-7817B9688F61"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:intel:xmm_7560:m.2:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "65DA746B-280F-4E5C-A944-561D6620611B"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html" ,
"source" : "secure@intel.com" ,
"tags" : [
"Vendor Advisory"
]
}
]
}