2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-32534" ,
"sourceIdentifier" : "psirt@bosch.com" ,
"published" : "2022-06-23T17:15:13.700" ,
2023-06-29 16:00:34 +00:00
"lastModified" : "2023-06-29T14:24:10.490" ,
2023-04-24 12:24:31 +02:00
"vulnStatus" : "Analyzed" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands."
} ,
{
"lang" : "es" ,
"value" : "El switch Ethernet de Bosch PRA-ES8P2S con la versi\u00f3n de software 1.01.05 y anteriores es vulnerable a una inyecci\u00f3n de comandos mediante su interfaz web de diagn\u00f3stico. Esto permite una ejecuci\u00f3n de comandos de shell"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
} ,
{
"source" : "psirt@bosch.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:L/Au:N/C:C/I:C/A:C" ,
"accessVector" : "NETWORK" ,
"accessComplexity" : "LOW" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "COMPLETE" ,
"integrityImpact" : "COMPLETE" ,
"availabilityImpact" : "COMPLETE" ,
"baseScore" : 10.0
} ,
"baseSeverity" : "HIGH" ,
"exploitabilityScore" : 10.0 ,
"impactScore" : 10.0 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : false
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
2023-06-29 16:00:34 +00:00
"value" : "CWE-78"
2023-04-24 12:24:31 +02:00
}
]
} ,
{
"source" : "psirt@bosch.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-20"
}
]
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:bosch:pra-es8p2s_firmware:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "1.01.05" ,
"matchCriteriaId" : "9F5BB28C-877A-49B1-B320-9033F3A80570"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:bosch:pra-es8p2s:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "8E5A4A92-8B68-4216-97EC-173AEDFBA1C2"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html" ,
"source" : "psirt@bosch.com" ,
"tags" : [
"Vendor Advisory"
]
}
]
}