110 lines
3.8 KiB
JSON
Raw Normal View History

2023-04-24 12:24:31 +02:00
{
"id": "CVE-2022-46823",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-01-10T12:15:23.753",
"lastModified": "2023-01-13T16:11:55.400",
"vulnStatus": "Analyzed",
"cveTags": [],
2023-04-24 12:24:31 +02:00
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.4), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.0 < V3.3.9), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Mendix SAML (compatible con Mendix 8) (Todas las versiones &gt;= V2.3.0 &lt; V2.3.4), Mendix SAML (compatible con Mendix 9, New Track) (Todas las versiones &gt;= V3.3.0 &lt; V3.3.9), Mendix SAML (compatible con Mendix 9, Upgrade Track) (Todas las versiones &gt;= V3.3.0 &lt; V3.3.8). El m\u00f3dulo afectado es vulnerable a ataques de cross-site scripting (XSS) reflejado. Esto podr\u00eda permitir a un atacante extraer informaci\u00f3n confidencial enga\u00f1ando a los usuarios para que accedan a un enlace malicioso."
2023-04-24 12:24:31 +02:00
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 9.3,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.8,
"impactScore": 5.8
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2.3.0",
"versionEndExcluding": "2.3.4",
"matchCriteriaId": "FA388A2C-406A-4911-96EC-ACB1574B83AC"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"versionStartIncluding": "3.3.0",
"versionEndExcluding": "3.3.9",
"matchCriteriaId": "506D83D7-350A-4586-83AE-93E56C61C5FE"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496604.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}