"id": "CVE-2023-50179",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2024-07-09T16:15:03.640",
"lastModified": "2024-07-09T18:18:38.713",
"vulnStatus": "Undergoing Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An improper certificate validation vulnerability [CWE-295] in FortiADC 7.4.0, 7.2 all versions, 7.1 all versions, 7.0 all versions may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the device and public SDN connectors."
},
{
"lang": "es",
"value": "Una vulnerabilidad de validaci\u00f3n de certificado incorrecta [CWE-295] en FortiADC 7.4.0, 7.2 todas las versiones, 7.1 todas las versiones, 7.0 todas las versiones puede permitir que un atacante remoto y no autenticado realice un ataque Man-in-the-Middle en el canal de comunicaci\u00f3n entre el dispositivo y los conectores SDN p\u00fablicos."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.2,
"impactScore": 2.5
}
]
},
"weaknesses": [
{
"source": "psirt@fortinet.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"references": [
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-480",
"source": "psirt@fortinet.com"
}
]
}