2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-46664" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2022-12-13T16:15:26.040" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T07:30:52.390" ,
2023-04-24 12:24:31 +02:00
"vulnStatus" : "Modified" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
2023-11-07 21:03:21 +00:00
"value" : "A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities.\r\n\r\nThis could allow authenticated remote attackers to read or delete sensitive information."
2024-04-04 08:46:00 +00:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en Mendix Workflow Commons (todas las versiones < V2.4.0), Mendix Workflow Commons V2.1 (todas las versiones < V2.1.4), Mendix Workflow Commons V2.3 (todas las versiones < V2.3.2) . Las versiones afectadas del m\u00f3dulo manejan incorrectamente el control de acceso para algunas entidades del m\u00f3dulo. Esto podr\u00eda permitir a atacantes remotos autenticados leer o eliminar informaci\u00f3n confidencial."
2023-04-24 12:24:31 +02:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
2024-12-08 03:06:42 +00:00
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
2023-04-24 12:24:31 +02:00
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 8.1 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.2
} ,
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 8.1 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.2
}
]
} ,
"weaknesses" : [
{
2024-04-04 08:46:00 +00:00
"source" : "productcert@siemens.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-284"
}
]
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-Other"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:mendix_workflow_commons:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "2.4.0" ,
"matchCriteriaId" : "681A5F97-59C5-460C-B769-6B54E9E51F4E"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-210822.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-210822.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}