"id": "CVE-2017-6028",
|
||
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
||
|
"published": "2017-06-30T03:29:00.360",
|
||
|
"lastModified": "2022-02-03T13:41:11.260",
|
||
|
"vulnStatus": "Analyzed",
|
||
|
"descriptions": [
|
||
|
{
|
||
|
"lang": "en",
|
||
|
"value": "An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application."
|
||
|
},
|
||
|
{
|
||
|
"lang": "es",
|
||
|
"value": "Un problema de credenciales protegidas insuficientemente fue detectado en PLCs Modicon M241, y Modicon M251 de Schneider Electric, en todas las versiones de firmware. Las credenciales de inicio de sesi\u00f3n se env\u00edan por medio de la red con codificaci\u00f3n Base64 dej\u00e1ndolas susceptibles a ser espiadas. Las credenciales espiadas se podr\u00edan usar para iniciar sesi\u00f3n en la aplicaci\u00f3n web."
|
||
|
}
|
||
|
],
|
||
|
"metrics": {
|
||
|
"cvssMetricV31": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"cvssData": {
|
||
|
"version": "3.1",
|
||
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||
|
"attackVector": "NETWORK",
|
||
|
"attackComplexity": "LOW",
|
||
|
"privilegesRequired": "NONE",
|
||
|
"userInteraction": "NONE",
|
||
|
"scope": "UNCHANGED",
|
||
|
"confidentialityImpact": "HIGH",
|
||
|
"integrityImpact": "HIGH",
|
||
|
"availabilityImpact": "HIGH",
|
||
|
"baseScore": 9.8,
|
||
|
"baseSeverity": "CRITICAL"
|
||
|
},
|
||
|
"exploitabilityScore": 3.9,
|
||
|
"impactScore": 5.9
|
||
|
}
|
||
|
],
|
||
|
"cvssMetricV2": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"cvssData": {
|
||
|
"version": "2.0",
|
||
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
|
||
|
"accessVector": "NETWORK",
|
||
|
"accessComplexity": "LOW",
|
||
|
"authentication": "NONE",
|
||
|
"confidentialityImpact": "PARTIAL",
|
||
|
"integrityImpact": "NONE",
|
||
|
"availabilityImpact": "NONE",
|
||
|
"baseScore": 5.0
|
||
|
},
|
||
|
"baseSeverity": "MEDIUM",
|
||
|
"exploitabilityScore": 10.0,
|
||
|
"impactScore": 2.9,
|
||
|
"acInsufInfo": false,
|
||
|
"obtainAllPrivilege": false,
|
||
|
"obtainUserPrivilege": false,
|
||
|
"obtainOtherPrivilege": false,
|
||
|
"userInteractionRequired": false
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
"weaknesses": [
|
||
|
{
|
||
|
"source": "nvd@nist.gov",
|
||
|
"type": "Primary",
|
||
|
"description": [
|
||
|
{
|
||
|
"lang": "en",
|
||
|
"value": "CWE-522"
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"source": "ics-cert@hq.dhs.gov",
|
||
|
"type": "Secondary",
|
||
|
"description": [
|
||
|
{
|
||
|
"lang": "en",
|
||
|
"value": "CWE-522"
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
],
|
||
|
"configurations": [
|
||
|
{
|
||
|
"operator": "AND",
|
||
|
"nodes": [
|
||
|
{
|
||
|
"operator": "OR",
|
||
|
"negate": false,
|
||
|
"cpeMatch": [
|
||
|
{
|
||
|
"vulnerable": true,
|
||
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*",
|
||
|
"versionEndIncluding": "4.0.3.20",
|
||
|
"matchCriteriaId": "9CA3FF3A-9145-4DAD-BAD6-D55C97E182AA"
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"operator": "OR",
|
||
|
"negate": false,
|
||
|
"cpeMatch": [
|
||
|
{
|
||
|
"vulnerable": false,
|
||
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*",
|
||
|
"matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C"
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"operator": "AND",
|
||
|
"nodes": [
|
||
|
{
|
||
|
"operator": "OR",
|
||
|
"negate": false,
|
||
|
"cpeMatch": [
|
||
|
{
|
||
|
"vulnerable": true,
|
||
|
"criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*",
|
||
|
"versionEndIncluding": "4.0.3.20",
|
||
|
"matchCriteriaId": "6FDB0710-FB7F-4346-9EEC-4C75ECEA0A1E"
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"operator": "OR",
|
||
|
"negate": false,
|
||
|
"cpeMatch": [
|
||
|
{
|
||
|
"vulnerable": false,
|
||
|
"criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*",
|
||
|
"matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0"
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
],
|
||
|
"references": [
|
||
|
{
|
||
|
"url": "http://www.securityfocus.com/bid/97254",
|
||
|
"source": "ics-cert@hq.dhs.gov",
|
||
|
"tags": [
|
||
|
"Third Party Advisory",
|
||
|
"VDB Entry"
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
|
||
|
"source": "ics-cert@hq.dhs.gov",
|
||
|
"tags": [
|
||
|
"Third Party Advisory",
|
||
|
"US Government Resource"
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
}
|