2024-08-12 14:03:14 +00:00
{
"id" : "CVE-2024-7697" ,
"sourceIdentifier" : "907edf6c-bf03-423e-ab1a-8da27e1aa1ea" ,
"published" : "2024-08-12T13:38:58.913" ,
2024-09-06 20:03:15 +00:00
"lastModified" : "2024-09-06T18:04:28.030" ,
"vulnStatus" : "Analyzed" ,
2024-08-12 14:03:14 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "Logical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks."
2024-08-18 02:03:12 +00:00
} ,
{
"lang" : "es" ,
"value" : "La vulnerabilidad l\u00f3gica en la aplicaci\u00f3n m\u00f3vil (com.transsion.carlcare) puede generar riesgos de fuga de informaci\u00f3n del usuario."
2024-08-12 14:03:14 +00:00
}
] ,
2024-08-12 16:03:13 +00:00
"metrics" : {
"cvssMetricV31" : [
2024-09-06 20:03:15 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH" ,
2024-09-06 20:03:15 +00:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2024-09-06 20:03:15 +00:00
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
} ,
2024-08-12 16:03:13 +00:00
{
"source" : "134c704f-9b21-4f2e-91b3-4a467353bcc0" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH" ,
2024-08-12 16:03:13 +00:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "NONE"
2024-08-12 16:03:13 +00:00
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
}
]
} ,
"weaknesses" : [
2024-09-06 20:03:15 +00:00
{
2024-12-08 03:06:42 +00:00
"source" : "907edf6c-bf03-423e-ab1a-8da27e1aa1ea" ,
"type" : "Secondary" ,
2024-09-06 20:03:15 +00:00
"description" : [
{
"lang" : "en" ,
2024-12-08 03:06:42 +00:00
"value" : "CWE-863"
2024-09-06 20:03:15 +00:00
}
]
} ,
2024-08-21 08:03:15 +00:00
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2024-08-21 08:03:15 +00:00
"description" : [
{
"lang" : "en" ,
2024-12-08 03:06:42 +00:00
"value" : "NVD-CWE-noinfo"
2024-08-21 08:03:15 +00:00
}
]
} ,
2024-08-12 16:03:13 +00:00
{
"source" : "134c704f-9b21-4f2e-91b3-4a467353bcc0" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-200"
}
]
}
] ,
2024-09-06 20:03:15 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:transsion:carlcare:5.9.5:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "62BC0308-86B9-4C2D-BB2E-54D7D87FFC17"
}
]
}
]
}
] ,
2024-08-12 14:03:14 +00:00
"references" : [
{
"url" : "https://security.tecno.com/SRC/blogdetail/294?lang=en_US" ,
2024-09-06 20:03:15 +00:00
"source" : "907edf6c-bf03-423e-ab1a-8da27e1aa1ea" ,
"tags" : [
"Vendor Advisory"
]
2024-08-12 14:03:14 +00:00
} ,
{
2024-08-21 08:03:15 +00:00
"url" : "https://security.tecno.com/SRC/securityUpdates?type=SA" ,
2024-09-06 20:03:15 +00:00
"source" : "907edf6c-bf03-423e-ab1a-8da27e1aa1ea" ,
"tags" : [
"Vendor Advisory"
]
2024-08-12 14:03:14 +00:00
}
]
}