2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-45093" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2023-01-10T12:15:23.523" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T07:28:46.053" ,
"vulnStatus" : "Modified" ,
2024-07-14 02:06:08 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component."
2024-09-15 02:03:16 +00:00
} ,
{
"lang" : "es" ,
"value" : "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones "
2023-04-24 12:24:31 +02:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
2024-12-08 03:06:42 +00:00
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
2023-04-24 12:24:31 +02:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H" ,
"baseScore" : 8.5 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
2024-12-08 03:06:42 +00:00
"attackComplexity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
2024-12-08 03:06:42 +00:00
"scope" : "CHANGED" ,
2023-04-24 12:24:31 +02:00
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
2024-12-08 03:06:42 +00:00
"exploitabilityScore" : 1.8 ,
"impactScore" : 6.0
2023-04-24 12:24:31 +02:00
} ,
{
2024-12-08 03:06:42 +00:00
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"cvssData" : {
"version" : "3.1" ,
2024-12-08 03:06:42 +00:00
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
2024-12-08 03:06:42 +00:00
"attackComplexity" : "LOW" ,
2023-04-24 12:24:31 +02:00
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
2024-12-08 03:06:42 +00:00
"scope" : "UNCHANGED" ,
2023-04-24 12:24:31 +02:00
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
2024-12-08 03:06:42 +00:00
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
2023-04-24 12:24:31 +02:00
}
]
} ,
"weaknesses" : [
{
"source" : "productcert@siemens.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-22"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "1.0" ,
"matchCriteriaId" : "C89891C1-DFD7-4E1F-80A9-7485D86A15B5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*" ,
"matchCriteriaId" : "4664B195-AF14-4834-82B3-0B2C98020EB6"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*" ,
"matchCriteriaId" : "75BC588E-CDF0-404E-AD61-02093A1DF343"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*" ,
"matchCriteriaId" : "A334F7B4-7283-4453-BAED-D2E01B7F8A6E"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" ,
"source" : "productcert@siemens.com" ,
"tags" : [
"Vendor Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}