2024-12-09 17:04:12 +00:00
{
"id" : "CVE-2024-49600" ,
"sourceIdentifier" : "security_alert@emc.com" ,
"published" : "2024-12-09T15:15:17.387" ,
2025-02-04 17:03:59 +00:00
"lastModified" : "2025-02-04T16:10:48.620" ,
"vulnStatus" : "Analyzed" ,
2024-12-09 17:04:12 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "Dell Power Manager (DPM), versions prior to 3.17, contain an improper access control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of Privileges."
2024-12-15 03:03:56 +00:00
} ,
{
"lang" : "es" ,
"value" : "Dell Power Manager (DPM), versiones anteriores a la 3.17, contienen una vulnerabilidad de control de acceso indebido. Un atacante con pocos privilegios y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la ejecuci\u00f3n de c\u00f3digo y la elevaci\u00f3n de privilegios."
2024-12-09 17:04:12 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "security_alert@emc.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
2025-02-04 17:03:59 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "LOW" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
2024-12-09 17:04:12 +00:00
}
]
} ,
"weaknesses" : [
{
"source" : "security_alert@emc.com" ,
2025-02-04 17:03:59 +00:00
"type" : "Secondary" ,
2024-12-09 17:04:12 +00:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-284"
}
]
2025-02-04 17:03:59 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "NVD-CWE-noinfo"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:power_manager:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "3.17" ,
"matchCriteriaId" : "E127BA99-9574-479F-8967-8FE0C4F7FDBF"
}
]
}
]
2024-12-09 17:04:12 +00:00
}
] ,
"references" : [
{
"url" : "https://www.dell.com/support/kbdoc/en-us/000244438/dsa-2024-439" ,
2025-02-04 17:03:59 +00:00
"source" : "security_alert@emc.com" ,
"tags" : [
"Vendor Advisory"
]
2024-12-09 17:04:12 +00:00
}
]
}