2023-06-13 10:00:30 +00:00
{
"id" : "CVE-2023-33124" ,
"sourceIdentifier" : "productcert@siemens.com" ,
"published" : "2023-06-13T09:15:18.500" ,
2023-06-21 22:00:32 +00:00
"lastModified" : "2023-06-21T20:40:11.047" ,
"vulnStatus" : "Analyzed" ,
2023-06-13 10:00:30 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process."
}
] ,
"metrics" : {
"cvssMetricV31" : [
2023-06-21 22:00:32 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
} ,
2023-06-13 10:00:30 +00:00
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
"attackVector" : "LOCAL" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 1.8 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
2023-06-21 22:00:32 +00:00
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-787"
}
]
} ,
2023-06-13 10:00:30 +00:00
{
"source" : "productcert@siemens.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-119"
}
]
}
] ,
2023-06-21 22:00:32 +00:00
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "14.2.0.3" ,
"matchCriteriaId" : "64B11DAF-8FFB-4696-85E5-67853B8A91F4"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.2.0" ,
"versionEndExcluding" : "13.2.0.13" ,
"matchCriteriaId" : "FC06105E-8D31-4AFD-88C6-2E58D01CFFE8"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "13.3.0" ,
"versionEndExcluding" : "13.3.0.10" ,
"matchCriteriaId" : "CAC2B735-3298-4B79-B98F-21916EE7926F"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "14.0" ,
"versionEndExcluding" : "14.0.0.6" ,
"matchCriteriaId" : "63AC2AB5-3593-4922-A4CC-E5E0E35DE071"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "14.1" ,
"versionEndExcluding" : "14.1.0.8" ,
"matchCriteriaId" : "F7D64A7C-AF27-4E09-9455-98BBF231CAF5"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*" ,
"versionStartIncluding" : "14.2" ,
"versionEndExcluding" : "14.2.0.3" ,
"matchCriteriaId" : "A5D5D267-7DE4-4116-878D-4422D9B5E7FD"
}
]
}
]
}
] ,
2023-06-13 10:00:30 +00:00
"references" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-538795.pdf" ,
2023-06-21 22:00:32 +00:00
"source" : "productcert@siemens.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-06-13 10:00:30 +00:00
}
]
}