"id": "CVE-2017-9964",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2018-01-02T03:29:00.267",
"lastModified": "2024-11-21T03:37:15.877",
2023-04-24 12:24:31 +02:00
"vulnStatus": "Modified",
"cveTags": [],
2023-04-24 12:24:31 +02:00
"descriptions": [
{
"lang": "en",
"value": "A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack."
},
{
"lang": "es",
"value": "Se descubri\u00f3 un problema de salto de directorio en todas las versiones anteriores a la 2.1 de Schneider Electric Pelco VideoXpert Enterprise. Al rastrear las comunicaciones, una persona no autorizada puede ejecutar un ataque de salto de directorio, resultando en una omisi\u00f3n de autenticaci\u00f3n o de secuestro de sesi\u00f3n."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
2023-04-24 12:24:31 +02:00
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
2023-04-24 12:24:31 +02:00
},
"exploitabilityScore": 1.6,
"impactScore": 4.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"baseScore": 5.8,
2023-04-24 12:24:31 +02:00
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE"
2023-04-24 12:24:31 +02:00
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:pelco_videoxpert:*:*:*:*:enterprise:*:*:*",
"versionEndExcluding": "2.1",
"matchCriteriaId": "81B30BAF-370B-44F2-AB13-FFDFBB6F32F0"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/102338",
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-355-02",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-339-01/",
"source": "cybersecurity@se.com"
},
{
"url": "http://www.securityfocus.com/bid/102338",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-355-02",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-339-01/",
"source": "af854a3a-2127-422b-91ae-364da2661108"