2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2020-14965" ,
"sourceIdentifier" : "cve@mitre.org" ,
"published" : "2020-06-23T14:15:12.823" ,
2024-11-23 13:10:58 +00:00
"lastModified" : "2024-11-21T05:04:31.830" ,
"vulnStatus" : "Modified" ,
2024-12-08 03:06:42 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "On TP-Link TL-WR740N v4 and TL-WR740ND v4 devices, an attacker with access to the admin panel can inject HTML code and change the HTML context of the target pages and stations in the access-control settings via targets_lists_name or hosts_lists_name. The vulnerability can also be exploited through a CSRF, requiring no authentication as an administrator."
} ,
{
"lang" : "es" ,
"value" : "En los dispositivos TP-Link TL-WR740N versi\u00f3n v4 y TL-WR740ND versi\u00f3n v4, un atacante con acceso al panel de administraci\u00f3n puede inyectar c\u00f3digo HTML y cambiar el contexto HTML de las p\u00e1ginas y estaciones de destino en la configuraci\u00f3n de control de acceso por medio de Target_lists_name o hosts_lists_name. La vulnerabilidad tambi\u00e9n puede ser explotada por medio de un ataque de tipo CSRF, que no requiere autenticaci\u00f3n como administrador"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N" ,
2024-11-23 13:10:58 +00:00
"baseScore" : 4.8 ,
"baseSeverity" : "MEDIUM" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "HIGH" ,
"userInteraction" : "REQUIRED" ,
"scope" : "CHANGED" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "LOW" ,
2024-11-23 13:10:58 +00:00
"availabilityImpact" : "NONE"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 1.7 ,
"impactScore" : 2.7
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:M/Au:S/C:N/I:P/A:N" ,
2024-11-23 13:10:58 +00:00
"baseScore" : 3.5 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "MEDIUM" ,
"authentication" : "SINGLE" ,
"confidentialityImpact" : "NONE" ,
"integrityImpact" : "PARTIAL" ,
2024-11-23 13:10:58 +00:00
"availabilityImpact" : "NONE"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "LOW" ,
"exploitabilityScore" : 6.8 ,
"impactScore" : 2.9 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : true
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-79"
}
]
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:tp-link:tl-wr740n_firmware:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "13CA99B0-BE20-4850-9D5E-2CC6020C4775"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:tp-link:tl-wr740n:4.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "63B5C5A3-E777-4BEA-96AF-914C49E6010E"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:tp-link:tl-wr740nd_firmware:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "FC328D98-029C-4754-8763-1FECC6E857AE"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:tp-link:tl-wr740nd:4.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "F04E05E9-01DE-447E-9A7F-B66756B817B6"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://github.com/g-rubert/CVE-2020-14965" ,
"source" : "cve@mitre.org" ,
"tags" : [
"Third Party Advisory"
]
2024-11-23 13:10:58 +00:00
} ,
{
"url" : "https://github.com/g-rubert/CVE-2020-14965" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Third Party Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}