2024-11-25 01:00:15 +00:00
{
"id" : "CVE-2024-11665" ,
"sourceIdentifier" : "research@onekey.com" ,
"published" : "2024-11-24T23:15:03.903" ,
2024-12-04 19:05:32 +00:00
"lastModified" : "2024-12-04T17:43:55.183" ,
"vulnStatus" : "Analyzed" ,
"cveTags" : [ ] ,
2024-11-25 01:00:15 +00:00
"descriptions" : [
{
"lang" : "en" ,
"value" : "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4."
2024-12-04 19:05:32 +00:00
} ,
{
"lang" : "es" ,
"value" : "La vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando ('Inyecci\u00f3n de comando') en hardy-barth cph2_echarge_firmware permite la inyecci\u00f3n de comandos del sistema operativo. Este problema afecta a cph2_echarge_firmware: hasta 2.0.4."
2024-11-25 01:00:15 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "research@onekey.com" ,
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
2024-12-04 19:05:32 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH" ,
"attackVector" : "ADJACENT_NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
"availabilityImpact" : "HIGH"
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
2024-11-25 01:00:15 +00:00
}
]
} ,
"weaknesses" : [
{
"source" : "research@onekey.com" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-77"
}
]
2024-12-04 19:05:32 +00:00
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-77"
}
]
}
] ,
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:echarge:salia_plcc_firmware:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "2.0.4" ,
"matchCriteriaId" : "68BE2BFC-8664-4D95-AB52-0724D268B9AA"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:echarge:salia_plcc:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "7ABECA31-3F68-4CAC-991F-7EC594A2A779"
}
]
}
]
2024-11-25 01:00:15 +00:00
}
] ,
"references" : [
{
"url" : "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers" ,
2024-12-04 19:05:32 +00:00
"source" : "research@onekey.com" ,
"tags" : [
"Exploit" ,
"Third Party Advisory"
]
2024-11-25 01:00:15 +00:00
}
]
}