2024-10-15 12:03:21 +00:00
{
"id" : "CVE-2024-45274" ,
"sourceIdentifier" : "info@cert.vde.com" ,
"published" : "2024-10-15T11:15:12.247" ,
2024-12-08 03:06:42 +00:00
"lastModified" : "2024-11-21T09:37:35.617" ,
"vulnStatus" : "Modified" ,
2024-10-15 12:03:21 +00:00
"cveTags" : [ ] ,
"descriptions" : [
{
"lang" : "en" ,
"value" : "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
2024-10-15 14:03:18 +00:00
} ,
{
"lang" : "es" ,
"value" : "Un atacante remoto no autenticado puede ejecutar comandos del sistema operativo a trav\u00e9s de UDP en el dispositivo debido a la falta de autenticaci\u00f3n."
2024-10-15 12:03:21 +00:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "info@cert.vde.com" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" ,
2024-12-08 03:06:42 +00:00
"baseScore" : 9.8 ,
"baseSeverity" : "CRITICAL" ,
2024-10-15 12:03:21 +00:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-12-08 03:06:42 +00:00
"availabilityImpact" : "HIGH"
2024-10-15 12:03:21 +00:00
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 5.9
}
]
} ,
"weaknesses" : [
{
"source" : "info@cert.vde.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2024-10-15 12:03:21 +00:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-306"
}
]
}
] ,
2024-10-17 18:03:18 +00:00
"configurations" : [
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:mbconnectline:mbnet.mini_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "2.3.1" ,
"matchCriteriaId" : "E4E80D53-0907-45AF-A03B-A093C5CEA33B"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:mbconnectline:mbnet.mini:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "A1D1B769-DA91-4F0C-AD34-D735B7A8B8FF"
}
]
}
]
} ,
{
"operator" : "AND" ,
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:o:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*" ,
"versionEndExcluding" : "2.3.1" ,
"matchCriteriaId" : "F226166A-1261-43F9-81EC-E1C0FC9CB6E6"
}
]
} ,
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : false ,
"criteria" : "cpe:2.3:h:helmholz:rex_100:-:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "E7E8BE39-3C4A-484A-A34D-3CB4B46E41FA"
}
]
}
]
}
] ,
2024-10-15 12:03:21 +00:00
"references" : [
{
"url" : "https://cert.vde.com/en/advisories/VDE-2024-056" ,
2024-10-17 18:03:18 +00:00
"source" : "info@cert.vde.com" ,
"tags" : [
"Third Party Advisory"
]
2024-10-15 12:03:21 +00:00
} ,
{
"url" : "https://cert.vde.com/en/advisories/VDE-2024-066" ,
2024-10-17 18:03:18 +00:00
"source" : "info@cert.vde.com" ,
"tags" : [
"Third Party Advisory"
]
2024-12-08 03:06:42 +00:00
} ,
{
"url" : "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108"
2024-10-15 12:03:21 +00:00
}
]
}