"id": "CVE-2024-7994",
"sourceIdentifier": "psirt@autodesk.com",
"published": "2024-10-16T22:15:03.353",
"lastModified": "2024-10-21T18:35:55.397",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A maliciously crafted RFA file, when parsed through Autodesk Revit, can force a Stack-Based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process."
},
{
"lang": "es",
"value": "Un archivo RFA manipulado con fines malintencionados, cuando se analiza a trav\u00e9s de Autodesk Revit, puede provocar un desbordamiento de b\u00fafer basado en pila. Un actor malintencionado puede aprovechar esta vulnerabilidad para provocar un bloqueo, leer datos confidenciales o ejecutar c\u00f3digo arbitrario en el contexto del proceso actual."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@autodesk.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "psirt@autodesk.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2024",
"versionEndExcluding": "2024.3",
"matchCriteriaId": "A5391738-3303-45EE-9530-0EE27781B541"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2025",
"versionEndExcluding": "2025.3",
"matchCriteriaId": "2A72AC7E-0FF8-4365-8FAB-17E805ECDC2F"
}
]
}
]
}
],
"references": [
{
"url": "https://autodesk.com/trust/security-advisories/adsk-sa-2024-0017",
"source": "psirt@autodesk.com",
"tags": [
"Vendor Advisory"
]
}
]
}