"id": "CVE-2024-5631",
"sourceIdentifier": "cvd@cert.pl",
"published": "2024-07-09T11:15:15.740",
"lastModified": "2024-08-01T22:15:32.220",
"vulnStatus": "Awaiting Analysis",
"cveTags": [
{
"sourceIdentifier": "cvd@cert.pl",
"tags": [
"unsupported-when-assigned"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Longse NVR (Network Video Recorder) model\u00a0NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.\u00a0\nThe credentials are being sent when a user decides to change his password in router's portal."
},
{
"lang": "es",
"value": " Longse NVR (Network Video Recorder) modelo NVR3608PGE2W, as\u00ed como los productos basados en este dispositivo, transmiten el nombre de usuario y la contrase\u00f1a a un servicio de control remoto sin utilizar ning\u00fan cifrado. Esto permite a un atacante en ruta espiar las credenciales y posteriormente obtener acceso a la transmisi\u00f3n de video. Las credenciales se env\u00edan cuando un usuario decide cambiar su contrase\u00f1a en el portal del enrutador."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"userInteraction": "PASSIVE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "NONE",
"vulnerableSystemAvailability": "NONE",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"baseScore": 6.0,
"baseSeverity": "MEDIUM"
}
}
]
},
"weaknesses": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"references": [
{
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/",
"source": "cvd@cert.pl"
},
{
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631",
"source": "cvd@cert.pl"
},
{
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01",
"source": "cvd@cert.pl"
}
]
}