97 lines
3.7 KiB
JSON
Raw Normal View History

{
"id": "CVE-2024-5634",
"sourceIdentifier": "cvd@cert.pl",
"published": "2024-07-09T11:15:16.283",
"lastModified": "2024-08-01T22:15:32.490",
"vulnStatus": "Awaiting Analysis",
"cveTags": [
{
"sourceIdentifier": "cvd@cert.pl",
"tags": [
"unsupported-when-assigned"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Longse model\u00a0LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.\u00a0\nAdditionally, every camera with the same firmware version shares the same password."
},
{
"lang": "es",
"value": "Las c\u00e1maras Longse modelo LBH30FE200W, as\u00ed como los productos basados en este dispositivo, utilizan contrase\u00f1as telnet que siguen un patr\u00f3n espec\u00edfico. Una vez que se conoce el patr\u00f3n, forzar la contrase\u00f1a por fuerza bruta se vuelve relativamente f\u00e1cil. Adem\u00e1s, cada c\u00e1mara con la misma versi\u00f3n de firmware comparte la misma contrase\u00f1a."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "HIGH",
"vulnerableSystemAvailability": "HIGH",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"baseScore": 8.6,
"baseSeverity": "HIGH"
}
}
]
},
"weaknesses": [
{
"source": "cvd@cert.pl",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-1391"
}
]
}
],
"references": [
{
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/",
"source": "cvd@cert.pl"
},
{
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631/",
"source": "cvd@cert.pl"
},
{
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01",
"source": "cvd@cert.pl"
}
]
}