2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-34444" ,
"sourceIdentifier" : "security_alert@emc.com" ,
"published" : "2023-02-11T01:23:24.613" ,
2023-11-07 21:03:21 +00:00
"lastModified" : "2023-11-07T03:48:41.857" ,
"vulnStatus" : "Modified" ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
2023-11-07 21:03:21 +00:00
"value" : "\nDell PowerScale OneFS, versions 9.2.0.x through 9.4.0.x contain an information vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to cause data leak.\n\n\n\n\n\n"
2023-04-24 12:24:31 +02:00
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 7.5 ,
"baseSeverity" : "HIGH"
} ,
"exploitabilityScore" : 3.9 ,
"impactScore" : 3.6
} ,
{
2024-04-04 08:46:00 +00:00
"source" : "security_alert@emc.com" ,
2023-04-24 12:24:31 +02:00
"type" : "Secondary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" ,
"attackVector" : "NETWORK" ,
"attackComplexity" : "HIGH" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "NONE" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "NONE" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 5.9 ,
"baseSeverity" : "MEDIUM"
} ,
"exploitabilityScore" : 2.2 ,
"impactScore" : 3.6
}
]
} ,
"weaknesses" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-327"
}
]
} ,
{
2024-04-04 08:46:00 +00:00
"source" : "security_alert@emc.com" ,
2023-04-24 12:24:31 +02:00
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-327"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:powerscale_onefs:9.2.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "B948CD53-3D17-4230-9B77-FCE8E0E548B9"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:powerscale_onefs:9.2.1:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "5AB99A1A-8DD3-4DDE-B70C-0E91D1D3B682"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:powerscale_onefs:9.3.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "61F14753-D64C-4E8B-AA94-07E014848B4D"
} ,
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:dell:powerscale_onefs:9.4.0:*:*:*:*:*:*:*" ,
"matchCriteriaId" : "A39208AE-D667-4B2A-AA65-1A6E35C19E1E"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://www.dell.com/support/kbdoc/en-us/000205618/dsa-2022-271" ,
"source" : "security_alert@emc.com" ,
"tags" : [
"Vendor Advisory"
]
}
]
}