{ "id": "CVE-2023-52365", "sourceIdentifier": "psirt@huawei.com", "published": "2024-02-18T03:15:08.850", "lastModified": "2024-12-09T17:17:30.053", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out-of-bounds read vulnerability in the smart activity recognition module.Successful exploitation of this vulnerability may cause features to perform abnormally." }, { "lang": "es", "value": "Vulnerabilidad de lectura fuera de los l\u00edmites en el m\u00f3dulo de reconocimiento de actividad inteligente. La explotaci\u00f3n exitosa de esta vulnerabilidad puede provocar que las funciones funcionen de manera anormal." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "baseScore": 5.3, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "LOW" }, "exploitabilityScore": 3.9, "impactScore": 1.4 } ] }, "weaknesses": [ { "source": "psirt@huawei.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-120" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-125" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:emui:12.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "A974CA73-84E8-480B-BB4C-4A81D0C985B2" }, { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:emui:13.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "353AEAF2-AF46-4835-93E1-4F942D5E2810" }, { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:harmonyos:2.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "20112231-B840-44D3-A061-B9B9F80EE378" }, { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:harmonyos:3.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "CB3751C1-7729-41D3-AE50-80B5AF601135" }, { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:harmonyos:3.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "4D81C4EF-7CAF-4E60-91A4-8CF7B95B2B54" }, { "vulnerable": true, "criteria": "cpe:2.3:o:huawei:harmonyos:4.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "8198CDB2-4BC5-411A-8736-615A531FC545" } ] } ] } ], "references": [ { "url": "https://consumer.huawei.com/en/support/bulletin/2024/2/", "source": "psirt@huawei.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://device.harmonyos.com/cn/docs/security/update/security-bulletins-202402-0000001834855405", "source": "psirt@huawei.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://consumer.huawei.com/en/support/bulletin/2024/2/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] }, { "url": "https://device.harmonyos.com/cn/docs/security/update/security-bulletins-202402-0000001834855405", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }