{ "id": "CVE-2023-36635", "sourceIdentifier": "psirt@fortinet.com", "published": "2023-09-07T13:15:08.433", "lastModified": "2023-11-07T04:16:39.410", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API." }, { "lang": "es", "value": "Un control de acceso incorrecto en Fortinet FortiSwitchManager, versiones 7.2.0 a 7.2.2 y versiones 7.0.0 a 7.0.1, puede permitir que un usuario remoto autenticado con permisos de solo lectura modifique la configuraci\u00f3n de la interfaz a trav\u00e9s de la API." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 1.4 }, { "source": "psirt@fortinet.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 4.2 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] }, { "source": "psirt@fortinet.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-284" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "5B4A6B0D-1614-443B-8EBA-A8FBC2E1A832" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "331A1766-4EBA-4519-A8ED-E0DD68A187E9" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*", "matchCriteriaId": "2B73D78B-2270-45B7-854E-F985B8D88F3B" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*", "matchCriteriaId": "469E9E1C-154C-41CB-AC83-FBE5E6FA83EB" }, { "vulnerable": true, "criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*", "matchCriteriaId": "959248C7-DC92-4968-87F9-2A2CDF84F7BE" } ] } ] } ], "references": [ { "url": "https://fortiguard.com/psirt/FG-IR-22-174", "source": "psirt@fortinet.com", "tags": [ "Not Applicable", "Vendor Advisory" ] } ] }