{ "id": "CVE-2024-6079", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2024-08-13T18:15:32.443", "lastModified": "2024-08-14T02:07:05.410", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in the Rockwell Automation Emulate3D\u2122,\u00a0which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack." }, { "lang": "es", "value": "Existe una vulnerabilidad en Rockwell Automation Emulate3D\u2122, que podr\u00eda aprovecharse para ejecutar un ataque de secuestro de DLL. La aplicaci\u00f3n carga librer\u00edas compartidas, que cualquier usuario puede leer y escribir. Si se explota, un usuario malintencionado podr\u00eda aprovechar una DLL maliciosa y realizar un ataque de ejecuci\u00f3n remota de c\u00f3digo." } ], "metrics": { "cvssMetricV40": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "attackVector": "LOCAL", "attackComplexity": "HIGH", "attackRequirements": "NONE", "privilegesRequired": "LOW", "userInteraction": "ACTIVE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "baseScore": 5.4, "baseSeverity": "MEDIUM" } } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-610" } ] } ], "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201683.html", "source": "PSIRT@rockwellautomation.com" } ] }