{ "id": "CVE-2023-46717", "sourceIdentifier": "psirt@fortinet.com", "published": "2024-03-12T15:15:46.487", "lastModified": "2024-03-21T21:04:18.200", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper authentication vulnerability [CWE-287] in FortiOS versions 7.4.1 and below, versions 7.2.6 and below, and versions 7.0.12 and below when configured with FortiAuthenticator in HA may allow a readonly user to gain read-write access via successive login attempts." }, { "lang": "es", "value": "Una vulnerabilidad de autenticaci\u00f3n incorrecta [CWE-287] en las versiones 7.4.1 y anteriores de FortiOS, las versiones 7.2.6 y siguientes y las versiones 7.0.12 y siguientes cuando se configura con FortiAuthenticator en HA puede permitir que un usuario de solo lectura obtenga acceso de lectura y escritura a trav\u00e9s de intentos sucesivos de inicio de sesi\u00f3n." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "psirt@fortinet.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "HIGH", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.6, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "psirt@fortinet.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-287" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.0.0", "versionEndExcluding": "7.0.13", "matchCriteriaId": "D25F9C04-C7FD-4B1F-A194-CA69E5DE903C" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.2.0", "versionEndExcluding": "7.2.7", "matchCriteriaId": "553C4BA9-953B-4017-8498-785BDA7A3006" }, { "vulnerable": true, "criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*", "versionStartIncluding": "7.4.0", "versionEndExcluding": "7.4.2", "matchCriteriaId": "4316C2EA-3D6E-4A0C-B81D-ADCE040E03E0" } ] } ] } ], "references": [ { "url": "https://fortiguard.com/psirt/FG-IR-23-424", "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ] } ] }