{ "id": "CVE-2024-23812", "sourceIdentifier": "productcert@siemens.com", "published": "2024-02-13T09:15:49.953", "lastModified": "2024-02-13T14:01:00.987", "vulnStatus": "Awaiting Analysis", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones < V2.0 SP1). La aplicaci\u00f3n afectada neutraliza incorrectamente elementos especiales al crear un informe, lo que podr\u00eda dar lugar a la inyecci\u00f3n de comandos." } ], "metrics": { "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.1, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-78" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-943925.html", "source": "productcert@siemens.com" } ] }