{ "id": "CVE-2016-2291", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2016-04-06T23:59:17.663", "lastModified": "2022-01-31T19:43:33.753", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors." }, { "lang": "es", "value": "Pro-face GP-Pro EX EX-ED en versiones anteriores a 4.05.000, PFXEXEDV en versiones anteriores a 4.05.000, PFXEXEDLS en versiones anteriores a 4.05.000 y PFXEXGRPLS en versiones anteriores a 4.05.000 permite a atacantes remotos ejecutar c\u00f3digo arbitrario o causar denegaci\u00f3n de servicio (lectura fuera de rango) a trav\u00e9s de vectores no especificados." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-125" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:proface_gp-pro_ex_ex-ed:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.0.4", "matchCriteriaId": "A2514428-2463-432A-940A-5C46E56B1989" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:proface_gp-pro_ex_pfxexedls:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.0.4", "matchCriteriaId": "5337F7BF-3352-456A-B11D-F481874B4CD0" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:proface_gp-pro_ex_pfxexedv:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.0.4", "matchCriteriaId": "D3FF0F1A-D633-40D7-8AE4-0F36419113FF" }, { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:proface_gp-pro_ex_pfxexgrpls:*:*:*:*:*:*:*:*", "versionEndIncluding": "4.0.4", "matchCriteriaId": "4EF38666-B916-410C-993C-5386186CCDCE" } ] } ] } ], "references": [ { "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-096-01", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }