{ "id": "CVE-2017-14022", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2017-12-23T00:29:13.230", "lastModified": "2019-10-09T23:23:45.077", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate." }, { "lang": "es", "value": "Se ha descubierto un problema de validaci\u00f3n de entrada incorrecta en Rockwell Automation FactoryTalk Alarms and Events, versi\u00f3n 2.90 y anteriores. Un atacante sin autenticar con acceso remoto a red y con FactoryTalk Alarms and Events puede enviar un paquete que incluya un grupo de paquetes manipulados al puerto 403/TCP (el servicio archivador de historiales), lo que provocar\u00eda que el servicio se bloquease o se cerrase." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-20" } ] }, { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-20" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_alarms_and_events:*:*:*:*:*:*:*:*", "versionEndIncluding": "2.90", "matchCriteriaId": "91F93E49-1C0C-4655-8D26-82857D65D36D" } ] } ] } ], "references": [ { "url": "http://www.securityfocus.com/bid/102114", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-341-02", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] } ] }