{ "id": "CVE-2018-5474", "sourceIdentifier": "ics-cert@hq.dhs.gov", "published": "2018-03-26T14:29:00.713", "lastModified": "2019-10-09T23:41:26.610", "vulnStatus": "Modified", "descriptions": [ { "lang": "en", "value": "Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash." }, { "lang": "es", "value": "Philips IntelliSpace Portal, en todas las versiones 7.0.x y 8.0.x, contiene una vulnerabilidad de validaci\u00f3n de entradas que podr\u00eda permitir a n atacante remoto ejecutar c\u00f3digo arbitrario o provocar el cierre inesperado de la aplicaci\u00f3n." } ], "metrics": { "cvssMetricV30": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 7.5 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-20" } ] }, { "source": "ics-cert@hq.dhs.gov", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-20" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "374B9A63-793D-41A1-A02F-4642031DA5FA" }, { "vulnerable": true, "criteria": "cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "784EBE3C-D9CB-433E-BC1D-4403B3BAB6AA" } ] } ] } ], "references": [ { "url": "http://www.securityfocus.com/bid/103182", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02", "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ] }, { "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security", "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ] } ] }