{ "id": "CVE-2020-7478", "sourceIdentifier": "cybersecurity@se.com", "published": "2020-03-23T20:15:12.370", "lastModified": "2024-11-21T05:37:13.563", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled." }, { "lang": "es", "value": "Una CWE-22: Se presenta una Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido en IGSS (Versiones 14 y anteriores al uso del servicio: IGSSupdate), lo que podr\u00eda permitir a un atacante remoto no autenticado leer archivos arbitrarios desde la PC del servidor IGSS en una red sin restricciones o compartida cuando el IGSS Update Service est\u00e1 habilitado." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "baseScore": 5.0, "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-22" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*", "versionStartIncluding": "14.0", "versionEndExcluding": "14.0.0.20009", "matchCriteriaId": "A6131D00-9397-4EE5-A369-004DEEC8AC5F" } ] } ] } ], "references": [ { "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/", "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-371/", "source": "cybersecurity@se.com", "tags": [ "Third Party Advisory", "VDB Entry" ] }, { "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-371/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ] } ] }