{ "id": "CVE-2020-15486", "sourceIdentifier": "cve@mitre.org", "published": "2020-08-26T16:15:12.683", "lastModified": "2021-07-21T11:39:23.747", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Dr Trust ECG Pen 2.00.08 devices. Because the Bluetooth LE support is implemented without a requirement for pairing or security, any attacker can access the GATT server of the device and can sniff the data being broadcasted while a measurement is being done. Also, saved data can also be extracted over a Bluetooth connection. In addition, an attacker can launch a man-in-the-middle attack against data integrity." }, { "lang": "es", "value": "Se detect\u00f3 un problema en los dispositivos Dr Trust ECG Pen versi\u00f3n 2.00.08. Porque la compatibilidad con Bluetooth LE es implementada sin un requisito de emparejamiento o seguridad, cualquier atacante puede acceder al servidor GATT del dispositivo y puede rastrear los datos que han sido transmitidos mientras ha sido realizada una medici\u00f3n. Adem\u00e1s, los datos guardados tambi\u00e9n pueden ser extra\u00eddos a trav\u00e9s de una conexi\u00f3n Bluetooth. Adem\u00e1s, un atacante puede iniciar un ataque de tipo man-in-the-middle contra la integridad de los datos" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "attackVector": "ADJACENT_NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "accessVector": "ADJACENT_NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3 }, "baseSeverity": "LOW", "exploitabilityScore": 6.5, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:drtrust:electrocardiogram_pen_firmware:2.00.08:*:*:*:*:*:*:*", "matchCriteriaId": "DEC90897-AD8D-4072-A28E-6326302F64EE" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:drtrust:electrocardiogram_pen:2.00.08:*:*:*:*:*:*:*", "matchCriteriaId": "33AFB885-737E-419E-AB0B-905B7B54D700" } ] } ] } ], "references": [ { "url": "https://payatu.com/advisory/lack-of-bluetooth-le-encryption-and-access-control-in-dr-trust-ecg-or-ekg-pen", "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ] } ] }