{ "id": "CVE-2020-26081", "sourceIdentifier": "ykramarz@cisco.com", "published": "2020-11-18T18:15:12.167", "lastModified": "2020-11-25T17:25:52.727", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Multiple vulnerabilities in the web UI of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against users on an affected system. The vulnerabilities are due to insufficient validation of user-supplied input that is processed by the web UI. An attacker could exploit these vulnerabilities by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information on an affected system." }, { "lang": "es", "value": "M\u00faltiples vulnerabilidades en la interfaz de usuario web de Cisco IoT Field Network Director (FND), podr\u00edan permitir a un atacante remoto no autenticado llevar a cabo ataques de tipo cross-site scripting (XSS) contra usuarios en un sistema afectado. Las vulnerabilidades son debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario que es procesada por la interfaz de usuario web. Un atacante podr\u00eda explotar estas vulnerabilidades persuadiendo a un usuario para que haga clic en un enlace creado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo de secuencia de comandos arbitrario en el contexto de la interfaz o acceder a informaci\u00f3n confidencial basada en navegador en un sistema afectado" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV30": [ { "source": "ykramarz@cisco.com", "type": "Secondary", "cvssData": { "version": "3.0", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 2.7 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE", "baseScore": 4.3 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-74" } ] }, { "source": "ykramarz@cisco.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-74" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:cisco:iot_field_network_director:*:*:*:*:*:*:*:*", "versionEndExcluding": "4.6.1", "matchCriteriaId": "0D507A4F-4079-4B68-997E-88901E063348" } ] } ] } ], "references": [ { "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-FND-XSS-NzOPCGEc", "source": "ykramarz@cisco.com", "tags": [ "Vendor Advisory" ] } ] }