{ "id": "CVE-2022-25786", "sourceIdentifier": "VulnerabilityReporting@secomea.com", "published": "2022-05-04T18:15:09.770", "lastModified": "2022-05-13T17:37:23.627", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7." }, { "lang": "es", "value": "Una vulnerabilidad del canal alternativo no protegido en la consola de depuraci\u00f3n de GateManager permite al administrador del sistema obtener informaci\u00f3n confidencial. Este problema afecta a: GateManager todas las versiones anteriores a 9.7" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 3.6 }, { "source": "VulnerabilityReporting@secomea.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 1.2, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "SINGLE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 4.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] }, { "source": "VulnerabilityReporting@secomea.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-420" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:secomea:gatemanager:*:*:*:*:*:*:*:*", "versionEndExcluding": "9.7.622134021", "matchCriteriaId": "26D8840C-963D-4D0D-9080-178323D0C629" } ] } ] } ], "references": [ { "url": "https://www.secomea.com/support/cybersecurity-advisory/", "source": "VulnerabilityReporting@secomea.com", "tags": [ "Vendor Advisory" ] } ] }