{ "id": "CVE-2024-37039", "sourceIdentifier": "cybersecurity@se.com", "published": "2024-06-12T17:15:51.313", "lastModified": "2024-11-21T09:23:06.010", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the\ndevice when an attacker sends a specially crafted HTTP request." }, { "lang": "es", "value": "CWE-252: Existe una vulnerabilidad de valor de retorno no verificado que podr\u00eda causar denegaci\u00f3n de servicio del dispositivo cuando un atacante env\u00eda una solicitud HTTP especialmente manipulada." } ], "metrics": { "cvssMetricV31": [ { "source": "cybersecurity@se.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 5.9, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "HIGH", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 2.2, "impactScore": 3.6 }, { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "availabilityImpact": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-252" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "c3414-500-s02k5_p9", "matchCriteriaId": "D4DDD3DD-576C-404E-A132-D1357936A610" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E606BD-92F8-4396-AD13-666D76E1E34D" }, { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*", "matchCriteriaId": "97E29CCC-4E21-411E-80DD-545A66E9B042" }, { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66759867-027F-4FA6-ABA6-BFDEE49E8F8D" }, { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*", "matchCriteriaId": "AA561E2A-4787-48D7-ABBB-26D0D7D24E6F" }, { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*", "matchCriteriaId": "453696F2-0F4C-4000-A438-F814D0FC3504" }, { "vulnerable": false, "criteria": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*", "matchCriteriaId": "6462B366-8F9F-49D6-939A-E73C1D5A707C" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf", "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ] }, { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ] } ] }