{ "id": "CVE-2024-37368", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2024-06-14T15:15:52.100", "lastModified": "2025-01-31T15:44:29.627", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A user authentication vulnerability exists in the Rockwell Automation\u00a0FactoryTalk\u00ae View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification." }, { "lang": "es", "value": "Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Debido a la falta de autenticaci\u00f3n adecuada, esta acci\u00f3n se permite sin una verificaci\u00f3n de autenticaci\u00f3n adecuada." } ], "metrics": { "cvssMetricV40": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 8.2, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "baseScore": 7.5, "baseSeverity": "HIGH", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-287" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-306" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*", "versionStartIncluding": "11.0", "versionEndExcluding": "14.0", "matchCriteriaId": "A0FFEADC-A55F-449A-9063-B0152A366906" } ] } ] } ], "references": [ { "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1676.html", "source": "PSIRT@rockwellautomation.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1676.html", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }