{ "id": "CVE-2020-25230", "sourceIdentifier": "productcert@siemens.com", "published": "2020-12-14T21:15:19.863", "lastModified": "2020-12-16T18:23:18.637", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en LOGO! 8 BM (incluyendo variantes SIPLUS) (Todas las versiones anteriores a V8.3). Debido al uso de un modo de cifrado desactualizado en el puerto 10005/tcp, un atacante podr\u00eda extraer la clave de cifrado de una comunicaci\u00f3n capturada con el dispositivo" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0 }, "baseSeverity": "MEDIUM", "exploitabilityScore": 10.0, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-327" } ] } ], "configurations": [ { "operator": "AND", "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:o:siemens:logo\\!_8_bm_firmware:*:*:*:*:*:*:*:*", "versionEndExcluding": "8.3", "matchCriteriaId": "2FA7BA89-3BF0-4C68-AC47-951B1F11F96D" } ] }, { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": false, "criteria": "cpe:2.3:h:siemens:logo\\!_8_bm:-:*:*:*:*:*:*:*", "matchCriteriaId": "59947FF6-3711-47C1-B91E-87DBF31DAF57" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480824.pdf", "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ] } ] }