{ "id": "CVE-2023-52952", "sourceIdentifier": "productcert@siemens.com", "published": "2024-10-08T09:15:10.097", "lastModified": "2024-10-10T12:56:30.817", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (All versions >= V11.5.1 < V11.6.2). The Kiosk Mode of the affected devices contains a restricted desktop environment escape vulnerability. This could allow an unauthenticated local attacker to escape the restricted environment and gain access to the underlying operating system." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en HiMed Cockpit 12 pro (J31032-K2017-H259) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (todas las versiones >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (todas las versiones >= V11.5.1 < V11.6.2). El modo quiosco de los dispositivos afectados contiene una vulnerabilidad de escape del entorno de escritorio restringido. Esto podr\u00eda permitir que un atacante local no autenticado escape del entorno restringido y obtenga acceso al sistema operativo subyacente." } ], "metrics": { "cvssMetricV40": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 9.3, "baseSeverity": "CRITICAL", "attackVector": "LOCAL", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "userInteraction": "NONE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "LOW", "subsequentSystemIntegrity": "LOW", "subsequentSystemAvailability": "HIGH", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NOT_DEFINED", "recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED" } } ], "cvssMetricV31": [ { "source": "productcert@siemens.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H", "baseScore": 8.5, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "HIGH" }, "exploitabilityScore": 2.5, "impactScore": 5.3 } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-424" } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-540493.html", "source": "productcert@siemens.com" } ] }