{ "id": "CVE-2020-7529", "sourceIdentifier": "cybersecurity@se.com", "published": "2020-09-16T16:15:15.310", "lastModified": "2024-11-21T05:37:19.190", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Limitaci\u00f3n Inapropiada de un Nombre de Ruta a un Directorio Restringido (\"Path Transversal\") CWE-22, en SCADAPack 7x Remote Connect (versiones V3.6.3.574 y anteriores) que permite a un atacante colocar contenido en cualquier carpeta desprotegida del sistema de destino usando un archivo .RCZ dise\u00f1ado" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N", "baseScore": 5.5, "baseSeverity": "MEDIUM", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "availabilityImpact": "NONE" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "baseScore": 4.3, "accessVector": "NETWORK", "accessComplexity": "MEDIUM", "authentication": "NONE", "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "availabilityImpact": "NONE" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 8.6, "impactScore": 2.9, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-22" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:scadapack_7x_remote_connect:*:*:*:*:*:*:*:*", "versionEndIncluding": "3.6.3.574", "matchCriteriaId": "3412A93E-4C9E-4B0E-9798-201E04241A34" } ] } ] } ], "references": [ { "url": "https://www.se.com/ww/en/download/document/SEVD-2020-252-01/", "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ] }, { "url": "https://www.se.com/ww/en/download/document/SEVD-2020-252-01/", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ] } ] }