{ "id": "CVE-2020-7583", "sourceIdentifier": "productcert@siemens.com", "published": "2020-08-14T16:15:17.727", "lastModified": "2024-11-21T05:37:25.093", "vulnStatus": "Modified", "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing." }, { "lang": "es", "value": "Una vulnerabilidad ha sido identificada en Automation License Manager 5 (Todas las versiones), Automation License Manager 6 (Todas las versiones anteriores a V6.0.8). La aplicaci\u00f3n no comprueba apropiadamente los privilegios de los usuarios cuando ejecutan algunas operaciones, lo que podr\u00eda permitir a un usuario con pocos permisos modificar arbitrariamente archivos que deber\u00edan estar protegidos contra escritura." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "baseScore": 4.6, "accessVector": "LOCAL", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL" }, "baseSeverity": "MEDIUM", "exploitabilityScore": 3.9, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "productcert@siemens.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-285" } ] }, { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-863" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:siemens:automation_license_manager:*:*:*:*:*:*:*:*", "versionStartIncluding": "5.0.0", "versionEndExcluding": "6.0.8", "matchCriteriaId": "41EB5114-158B-4672-9688-3F312EEC9940" } ] } ] } ], "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf", "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ] }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ] } ] }