{ "id": "CVE-2022-24310", "sourceIdentifier": "cybersecurity@se.com", "published": "2022-02-09T23:15:19.647", "lastModified": "2022-02-17T02:28:10.480", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)" }, { "lang": "es", "value": "Una CWE-190: Se presenta una vulnerabilidad de Desbordamiento de Enteros o Wraparound que podr\u00eda causar un desbordamiento del b\u00fafer en la regi\u00f3n heap de la memoria, conllevando a una denegaci\u00f3n de servicio y potencialmente una ejecuci\u00f3n de c\u00f3digo remota cuando un atacante env\u00eda m\u00faltiples mensajes especialmente dise\u00f1ados. Producto afectado: Interactive Graphical SCADA System Data Server (versiones V15.0.0.22020 y anteriores)" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } ], "cvssMetricV2": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 7.5 }, "baseSeverity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false } ] }, "weaknesses": [ { "source": "cybersecurity@se.com", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-190" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:*", "versionEndIncluding": "15.0.0.22020", "matchCriteriaId": "6418CE35-66F8-4EA4-9C84-4396FF70C773" } ] } ] } ], "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01", "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ] } ] }