{ "id": "CVE-2022-38743", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2022-10-17T21:15:10.343", "lastModified": "2022-10-19T17:55:40.100", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data." }, { "lang": "es", "value": "Rockwell Automation FactoryTalk VantagePoint versiones 8.0, 8.10, 8.20, 8.30, 8.31, son susceptibles a una vulnerabilidad de control de acceso inapropiada. La cuenta de FactoryTalk VantagePoint SQL Server podr\u00eda permitir a un usuario malicioso con privilegios de s\u00f3lo lectura ejecutar sentencias SQL en la base de datos del back-end. Si es explotado con \u00e9xito, esto podr\u00eda permitir al atacante ejecutar c\u00f3digo arbitrario y conseguir acceso a datos restringidos" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] }, { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-284" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "CAD07421-BA29-47E8-B96B-424C35194F2F" }, { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.10:*:*:*:*:*:*:*", "matchCriteriaId": "5F68655B-5ED9-4B1C-9E7E-4374F5A31AFE" }, { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.20:*:*:*:*:*:*:*", "matchCriteriaId": "272D6C41-9E30-4A70-BAD7-A94D8EE51167" }, { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.30:*:*:*:*:*:*:*", "matchCriteriaId": "43E695DF-8CB1-49AA-BFEC-18336C2FCF8D" }, { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.31:*:*:*:*:*:*:*", "matchCriteriaId": "EA050720-1DC3-4B74-9AE4-5212D4A81938" } ] } ] } ], "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043", "source": "PSIRT@rockwellautomation.com", "tags": [ "Permissions Required", "Vendor Advisory" ] } ] }