{ "id": "CVE-2023-2444", "sourceIdentifier": "PSIRT@rockwellautomation.com", "published": "2023-05-11T19:15:09.437", "lastModified": "2023-05-20T00:41:38.177", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nA cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.\u00a0\u00a0Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.\n\n" } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH" }, "exploitabilityScore": 2.8, "impactScore": 5.9 }, { "source": "PSIRT@rockwellautomation.com", "type": "Secondary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "HIGH", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH" }, "exploitabilityScore": 1.6, "impactScore": 5.5 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-352" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:*:*:*:*:*:*:*:*", "versionEndExcluding": "8.40", "matchCriteriaId": "2FA4CAEA-C5FC-459F-86A1-8CB3D39FCA15" } ] } ] } ], "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139443", "source": "PSIRT@rockwellautomation.com", "tags": [ "Permissions Required", "Vendor Advisory" ] } ] }