{ "id": "CVE-2024-6051", "sourceIdentifier": "cvd@cert.pl", "published": "2024-09-30T13:15:02.800", "lastModified": "2024-10-04T13:51:25.567", "vulnStatus": "Awaiting Analysis", "cveTags": [], "descriptions": [ { "lang": "en", "value": "Cross Application Scripting vulnerability in Vercom S.A. Redlink SDK\u00a0in specific situations allows local code injection and to manipulate the view of a vulnerable application.This issue affects Redlink SDK versions through 1.13." }, { "lang": "es", "value": "La vulnerabilidad de secuencias de comandos entre aplicaciones en el SDK de Vercom SA Redlink en situaciones espec\u00edficas permite la inyecci\u00f3n de c\u00f3digo local y la manipulaci\u00f3n de la vista de una aplicaci\u00f3n vulnerable. Este problema afecta a las versiones del SDK de Redlink hasta la 1.13." } ], "metrics": { "cvssMetricV40": [ { "source": "cvd@cert.pl", "type": "Secondary", "cvssData": { "version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:A/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:U/V:D/RE:L/U:Clear", "attackVector": "LOCAL", "attackComplexity": "HIGH", "attackRequirements": "PRESENT", "privilegesRequired": "HIGH", "userInteraction": "ACTIVE", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "HIGH", "vulnerableSystemAvailability": "LOW", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "subsequentSystemAvailability": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "safety": "NOT_DEFINED", "automatable": "NO", "recovery": "USER", "valueDensity": "DIFFUSE", "vulnerabilityResponseEffort": "LOW", "providerUrgency": "CLEAR", "baseScore": 4.3, "baseSeverity": "MEDIUM" } } ] }, "weaknesses": [ { "source": "cvd@cert.pl", "type": "Secondary", "description": [ { "lang": "en", "value": "CWE-99" } ] } ], "references": [ { "url": "https://cert.pl/en/posts/2024/09/CVE-2024-6051/", "source": "cvd@cert.pl" }, { "url": "https://cert.pl/posts/2024/09/CVE-2024-6051/", "source": "cvd@cert.pl" } ] }