{ "id": "CVE-2022-38765", "sourceIdentifier": "cve@mitre.org", "published": "2022-12-09T00:15:10.063", "lastModified": "2022-12-12T18:00:02.313", "vulnStatus": "Analyzed", "descriptions": [ { "lang": "en", "value": "Canon Medical Informatics Vitrea Vision 7.7.76.1 does not adequately enforce access controls. An authenticated user is able to gain unauthorized access to imaging records by tampering with the vitrea-view/studies/search patientId parameter." } ], "metrics": { "cvssMetricV31": [ { "source": "nvd@nist.gov", "type": "Primary", "cvssData": { "version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } ] }, "weaknesses": [ { "source": "nvd@nist.gov", "type": "Primary", "description": [ { "lang": "en", "value": "CWE-639" } ] } ], "configurations": [ { "nodes": [ { "operator": "OR", "negate": false, "cpeMatch": [ { "vulnerable": true, "criteria": "cpe:2.3:a:canon:vitrea_view:*:*:*:*:*:*:*:*", "versionEndExcluding": "7.8", "matchCriteriaId": "C53DA1ED-4715-4DD2-8FBD-86E763B09AE0" } ] } ] } ], "references": [ { "url": "https://www.vitalimages.com/customer-success-support-program/vital-images-software-security-updates/", "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ] } ] }